FlexiSpec®

Spectroscopy Fiber Probes & Probe Couplers

FlexiRay®

Fibers | Cables | Bundles | Accessories

FlexiService

Loan & Installation | Measurements Training | Repair | Development
News
Latest News
2 September 2024
Viacheslav Artyushenko on the cover page of Magnate View Magazine!

We are thrilled to announce that our CEO & Founder, Viacheslav Artyushenko, graces the cover of Magnate View Magazine as one of the Top 5 Exceptional Leaders to Follow in 2024! Viacheslav's groundbreaking work in fiber optics, particularly with Mid-IR fibers, has positioned art photonics GmbH at the cutting edge of technological innovation. His visionary […]

Read more
20 August 2024
Application Note: Bioprocess Monitoring with Mid-Infrared Spectroscopy

We are thrilled to announce the release of our latest Application Note, detailing the advanced use of mid-infrared fiber spectroscopic techniques for real-time monitoring of biomass, ethanol, and crucial hydrocarbons during the yeast fermentation process. Traditional analytical methods often face challenges when dealing with the complexity and speed required in biotechnological processes. Our innovative approach, […]

Read more
Latest Events
26 August 2024
Mini-APACT 2024 | 8-9 October 2024, Macclesfield, UK

We're excited to announce that art photonics is proud to sponsor MiniAPACT 2024, a significant event for those committed to advancing the process industries. This year, we're supporting the theme "Developments in Application of Optical Techniques for PAT." This focus will include a half-day series of talks highlighting the latest innovations in Process Analytical Technology […]

Read more
4 July 2024
Optica Sensing Congress 2024 | 15-19 July 2024, Toulouse, France

We are happy to announce that our R&D Manager, Alexander Novikov, will be presenting at the Optica Sensing Congress 2024 in Toulouse, France! Join and explore our cutting-edge fiber-optic solutions designed for multispectral process-control in the 0.3-16µm range. Date: July 15, 2024Presentation Time: 11:00 AM - 11:15 AM CESTLocation: Session Room Ariane 2Session Title: Process […]

Read more
Resources
About Our Company
art photonics GmbH, founded in Berlin in September 1998, is one of the worldwide leaders in development and production of specialty fiber products for a broad spectrum from 300 nm to 16 µm. Unique technologies of Polycrystalline Mid InfraRed (PIR-) fibers and Metal coated Silica fibers are used for assembly of various spectroscopy probes for medical diagnostics and industrial process control, in volume production of fiber for medical and industrial lasers, for different fiber bundles, etc. Since January 2024 art photonics GmbH is a member of NYNOMIC GROUP.
UV 200-400 nm
Visible
Near IR 750-2500 nm
Mid IR 2.5 - 18 µm

Fiber Optic ATR-Probes for Harsh Environment

Main features:

  • High throughput in selected parts of Near & Mid InfraRed-spectra
  • ATR-tip shaped for immersion in liquid flow without dead zone
  • Robust for industrial applications in harsh environment up to 250°C
  • Resistant to high pressure
  • Compatible with all spectrometers and automated process-interfaces

Description

Fiber Optic ATR-Probes for harsh environment can be used for process-spectroscopy in Near & Mid IR range to monitor reactions in-line in a broad temperature range from -150° to +250°C. They can resist to high pressures up to 200 Bar and used with FTIR or any other IR-spectrometers and spectral sensors in automated process control with process-interfaces.

For more information please visit our “Downloads” section and find relative articles at our “Publications” page.

Specs

Common Parameters of Fiber Optic High Temperature (HT) – ATR-Probes
Total Length 1.5m (opt.: 1m to 5m)*
Shaft Length 300mm (opt.: 300-700mm)*
Shaft Diameter 6.3mm or 12mm
Shaft Material Hastelloy C22
Length of Legs 500mm (opt.: 200mm to 500mm)
Protective Tube Material Liquid Tight SS-Conduit, KOPEX-Tube
Minimal Bending Radius 130mm
Input / Output Connectors Long SMA (opt.: any other type)
Cooling Air Flow Parameters Excess pressure 0.5Bar, Flow 2300l/h
Inner temperature control Inside shaft to control ATR tip temperature
Specification of Fiber Optic High Temperature (HT) – ATR- Probes
Di-ATR Si- ATR ZrO₂- ATR ZnSe-ATR
Probe type
Transmission range 5.2-17μm

600-1900 cm-1

3.2-17μm

600-3100 cm-1

1.1-6.5μm

1550-9000 cm-1

3.2-17μm

600-3100 cm-1

Fiber type PIR-900/1000

Silver Halide

PIR-900/1000

Silver Halide

CIR-500/550

Chalcogenide glass

PIR-900/1000

Silver Halide

Temperature range -150°C / +250°C -150°C / +250°C -150°C / +200°C -150°C / +250°C
Pressure (max) 200 Bar 100 Bar 100 Bar 10 Bar

Downloads

Applications

  • Remote Reaction Monitoring in-line in temperature range -100/+250°C
  • PAT applications in lab, pilot plant or industry with process-interfaces for automated process control
  • Polymerization Process Control
  • In-situ IR-Spectroscopy for PAT in Chemical, Petrochemical, Atomic, Biopharmaceutical & Food Industry

Inquiry

Do you have any questions about this or any other product? Send us an inquiry, and our personnel will answer your question as soon as possible.

linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram
Copy link
Powered by Social Snap