FlexiSpec®

Spectroscopy Fiber Probes & Probe Couplers

FlexiRay®

Fibers | Cables | Bundles | Accessories

FlexiService

Loan & Installation | Measurements Training | Repair | Development
News
Latest News
16 October 2024
Leadership Update at art photonics GmbH

art photonics GmbH is pleased to announce that Dr. Stefanie Foerster has been appointed as the new CEO! Dr. Foerster brings extensive experience in general management, business development, and sales across diverse industries, including environmental, petrochemical, energy, and high-tech industries. She has held senior leadership roles at companies like thyssenkrupp and Siemens, where she has […]

Read more
23 September 2024
NEW: 3A-Certified Hygienic Transflection Fiber Probe

Introducing the 3A-Certified Transflection Fiber Probe for Enhanced Industrial Process Control As the food, beverage, and pharmaceutical industries rapidly evolve, maintaining precision and hygiene in production processes has never been more crucial. Our latest innovation, the 3A-Certified Hygienic Transflection Fiber Probe, is designed to meet the most stringent sanitary requirements while delivering real-time, in-line NIR […]

Read more
Latest Events
22 October 2024
SciX 2024 | 20-25 October, 2024, Raleigh, NC, USA

Are you attending the SciX Conference this week? Don’t miss the opportunity to meet our Sales Director, Haro Fritsche, at the Avantes booth #511! Haro will be presenting art photonics' novel fiber optic probes designed for process-control in-line solutions, offering valuable insights into how our technologies can support your process analytical needs. Presentation Details: Title: […]

Read more
7 October 2024
Reminder: Mini-APACT 2024 | 8-9 October 2024, Macclesfield, UK

Just a few days left until Mini-APACT 2024! We’re excited to be part of Mini-APACT 2024 as sponsors of this year’s theme: "Developments in Application of Optical Techniques for PAT." It’s a fantastic opportunity to explore the latest advancements in Process Analytical Technology (PAT) through a series of engaging talks. Don’t miss our colleague Martin […]

Read more
Resources
About Our Company
art photonics GmbH, founded in Berlin in September 1998, is one of the worldwide leaders in development and production of specialty fiber products for a broad spectrum from 300 nm to 16 µm. Unique technologies of Polycrystalline Mid InfraRed (PIR-) fibers and Metal coated Silica fibers are used for assembly of various spectroscopy probes for medical diagnostics and industrial process control, in volume production of fiber for medical and industrial lasers, for different fiber bundles, etc. Since January 2024 art photonics GmbH is a member of NYNOMIC GROUP.
UV 200-400 nm
Visible
Near IR 750-2500 nm
Mid IR 2.5 - 18 µm

Fiber Optic ATR Loop Probe

Main features

  • High throughput at Mid InfraRed range
  • On-line absorbance spectroscopy of liquids, pastes & soft solid surfaces
  • Compatible with all FTIR, QCL and IR- Filter spectrometers
  • Cost effective alternative to more expensive ATR-IR-fiber probes
  • Replaceable ATR Loop PIR-Fiber Tips

Description

The ATR-Loop Infrared PIR-fiber probe was the first in FlexiSpec® product line designed for use with FTIR and other Mid IR spectrometers. ATR-Loop PIR-fiber probes are well-suited for remote analysis of composition of liquids, pastes and soft surfaces and do not require sample preparation. The Loop fiber probe is the simplest one in the FlexiSpec® product family to allow for low cost ATR-spectroscopy. Loops with different number of turns (single, double or triple) serve to fit the desired sensitivity.

For a detailed instruction of how to use the Loop Probe, please see:

For more information please visit our “Downloads” section and find relative articles at our “Publications” page.

Specs

Common Parameters of Fiber Optic Multi-Loop Probes FlexiSpec®
Total Length 1m (opt.: PIR up to 5m, CIR up to 10m) *
Shaft Length 120mm *
Shaft Diameter 10,6mm
Shaft Material PEEK
Protective Tube Material PEEK
Input / Output Connectors Long SMA-905 (opt.: any other type)
Detachable PIR fiber Loop Loop; Multi-Loop (Double-, Triple-Loop)
*Customized dimensions are available on request
Specification of Fiber Optic ATR-Loop Probes FlexiSpec®
Probe type Chalcogenide-IR (CIR) Polycrystalline-IR (PIR)
Transmission range 6500 – 1550 cm-1 (1.5-6.0μm) 2500 – 600 cm -1 (4-17μm)
Fiber type Chalcogenide glass (As-S) Silver Halide (AgCl:AgBr)
Temperature range ≤ 90°C ≤ 100°C

Graphs

Downloads

Applications

  • Remote evanescent absorption (ATR-) spectroscopy in-citu
  • Multiple ATR-spectroscopy by immersion of fiber loop in liquid
  • In-vivo molecular spectroscopy for medical diagnostics by simple touch of ATR-Loop on skin or tissue

Inquiry

Do you have any questions about this or any other product? Send us an inquiry, and our personnel will answer your question as soon as possible.

linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram
Copy link
Powered by Social Snap