FlexiSpec®

Spectroscopy Fiber Probes & Probe Couplers

FlexiRay®

Fibers | Cables | Bundles | Accessories

FlexiService

Loan & Installation | Measurements Training | Repair | Development
News
Latest News
27 April 2026
Introducing the FlexiSpec Combi Fiber Optic Probes

In the demanding fields of bio-pharma and advanced R&D, real-time data is essential. Traditionally, securing comprehensive analytical data meant physically switching between different spectroscopic setups, such as ATR, NIR, and Raman. This fragmented approach not only slows down critical processes but also introduces a higher risk of sampling errors. Why run three separate analyses when […]

Read more
17 March 2026
Application Note: Identification of Organic and Pharmaceutical Powders

Real-time, in-line powder identification usually means a trade-off between speed and accuracy. We proved it doesn't have to. We recently teamed up with our Nynomic Group partner, m-u-t GmbH, to release a joint Application Note. The goal was simple: build a compact, field-ready NIR setup capable of analyzing complex organics directly in the bulk material, […]

Read more
Latest Events
21 May 2026
View on EPIC Technology Meeting on Optical Fiber Sensors at Airbus

We recently had a fantastic time attending the EPIC Technology Meeting on Optical Fiber Sensors, hosted at Airbus in Hamburg. The event provided excellent networking opportunities with major companies in the aviation sector and served as a great platform to discuss the future of aerospace sensing. During the meeting, our Product Line Manager, Joachim Gerike, […]

Read more
15 May 2026
EPIC Technology Meeting on Optical Fiber Sensors at Airbus | 19-20 May 2026 | Hamburg, Germany

We are currently in Hamburg attending the EPIC Technology Meeting on Optical Fiber Sensors, hosted at Airbus. This gathering is a fantastic opportunity to connect with industry leaders and explore the latest advancements in fiber optic sensing technologies. For those attending the event, we invite you to join us today for Session 2: Fibers, Fiber […]

Read more
About Our Company
art photonics GmbH, founded in Berlin in September 1998, is one of the worldwide leaders in development and production of specialty fiber products for a broad spectrum from 300 nm to 16 µm. Unique technologies of Polycrystalline Mid InfraRed (PIR-) fibers and Metal coated Silica fibers are used for assembly of various spectroscopy probes for medical diagnostics and industrial process control, in volume production of fiber for medical and industrial lasers, for different fiber bundles, etc. Since January 2024 art photonics GmbH is a member of NYNOMIC GROUP.
Member Of:
UV 200-400 nm
Visible
Near IR 750-2500 nm
Mid IR 2.5 - 18 µm

Fiber Optic ATR Loop Probe

Main features

  • High throughput at Mid InfraRed range
  • On-line absorbance spectroscopy of liquids, pastes & soft solid surfaces
  • Compatible with all FTIR, QCL and IR- Filter spectrometers
  • Cost effective alternative to more expensive ATR-IR-fiber probes
  • Replaceable ATR Loop PIR-Fiber Tips
Excel LogoArtphotonics_Sale from stock Probes March 2026

Description

The ATR-Loop Infrared PIR-fiber probe was the first in FlexiSpec® product line designed for use with FTIR and other Mid IR spectrometers. ATR-Loop PIR-fiber probes are well-suited for remote analysis of composition of liquids, pastes and soft surfaces and do not require sample preparation. The Loop fiber probe is the simplest one in the FlexiSpec® product family to allow for low cost ATR-spectroscopy. Loops with different number of turns (single, double or triple) serve to fit the desired sensitivity.

For a detailed instruction of how to use the Loop Probe, please see:

You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.

More Information

For more information please visit our “Downloads” section and find relative articles at our “Publications” page.

Specs

Common Parameters of Fiber Optic Multi-Loop Probes FlexiSpec®
Total Length 1m (opt.: PIR up to 5m, CIR up to 10m) *
Shaft Length 120mm *
Shaft Diameter 10,6mm
Shaft Material PEEK
Protective Tube Material PEEK
Input / Output Connectors Long SMA-905 (opt.: any other type)
Detachable PIR fiber Loop Loop; Multi-Loop (Double-, Triple-Loop)
*Customized dimensions are available on request
Specification of Fiber Optic ATR-Loop Probes FlexiSpec®
Probe type Chalcogenide-IR (CIR) Polycrystalline-IR (PIR)
Transmission range 6500 – 1550 cm-1 (1.5-6.0μm) 2500 – 600 cm -1 (4-17μm)
Fiber type Chalcogenide glass (As-S) Silver Halide (AgCl:AgBr)
Temperature range ≤ 90°C ≤ 100°C

Graphs

Downloads

 

Applications

  • Remote evanescent absorption (ATR-) spectroscopy in-citu
  • Multiple ATR-spectroscopy by immersion of fiber loop in liquid
  • In-vivo molecular spectroscopy for medical diagnostics by simple touch of ATR-Loop on skin or tissue

Inquiry

Do you have any questions about this or any other product? Send us an inquiry, and our personnel will answer your question as soon as possible.

We use the Mailchimp service (Intuit Inc., USA) to distribute our newsletter. Your data is used exclusively for the purpose of sending the newsletter and will be processed based on your consent (Art. 6 para. 1 lit. a GDPR). Mailchimp may also process data in the United States. Please note that the USA is considered a third country without an adequate level of data protection. For more information, please refer to Mailchimp’s Privacy Policy: https://mailchimp.com/legal/privacy/ .
crossarrow-right
linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram
Copy link
Powered by Social Snap