FlexiSpec®

Spectroscopy Fiber Probes & Probe Couplers

FlexiRay®

Fibers | Cables | Bundles | Accessories

FlexiService

Loan & Installation | Measurements Training | Repair | Development
News
Latest News
21 November 2024
Stock Sale: Discounted IR Cables Available Now!

art photonics is excited to announce a special stock sale featuring discounted prices on our IR fibers and cables. These high-performance products are ideal for a variety of applications in spectroscopy, process monitoring, and industrial solutions. Take advantage of reduced pricing on the following IR fiber cables, available for immediate shipment: All products in this […]

Read more
2 November 2024
Join Our Team: Sales Manager Position Open at art photonics

art photonics GmbH is thrilled to announce an exciting career opportunity! We are looking for a motivated and experienced Sales Manager to join our team and drive growth in the European market. As a Sales Manager, you will play a key role in managing and developing customer relationships, with a focus on optical probes for […]

Read more
Latest Events
19 November 2024
Herbstkolloquium Prozessanalytik 2024 | 4–6 December 2024, Merck Darmstadt, Germany

art photonics GmbH is proud to announce its participation in the 19th Herbstkolloquium Prozessanalytik, taking place from December 4–6, 2024, at Merck Darmstadt. We will be showcasing our innovative fiber spectroscopy solutions for in-line process control at Booth №1, including: Additionally, our colleague Andrea Teuber will deliver a presentation, providing insights into the role of […]

Read more
11 November 2024
PIA 2024 | 19-21 November, 2024, Singapore EXPO, Singapore

Join art photonics at PIA 2024 in Singapore! art photonics GmbH, in collaboration with our partner tec5 AG, will be exhibiting at Booth E07 at Process Innovation Asia-Pacific (PIA) 2024. We invite you to visit us to explore our advanced fiber optics technologies for in-line process control. Our Fiber Optic Probes are specifically designed to […]

Read more
Resources
About Our Company
art photonics GmbH, founded in Berlin in September 1998, is one of the worldwide leaders in development and production of specialty fiber products for a broad spectrum from 300 nm to 16 µm. Unique technologies of Polycrystalline Mid InfraRed (PIR-) fibers and Metal coated Silica fibers are used for assembly of various spectroscopy probes for medical diagnostics and industrial process control, in volume production of fiber for medical and industrial lasers, for different fiber bundles, etc. Since January 2024 art photonics GmbH is a member of NYNOMIC GROUP.
Member Of:
UV 200-400 nm
Visible
Near IR 750-2500 nm
Mid IR 2.5 - 18 µm

Fiber Optic ATR-Probes for Harsh Environment

Main features:

  • High throughput in selected parts of Near & Mid InfraRed-spectra
  • ATR-tip shaped for immersion in liquid flow without dead zone
  • Robust for industrial applications in harsh environment up to 250°C
  • Resistant to high pressure
  • Compatible with all spectrometers and automated process-interfaces

Description

Fiber Optic ATR-Probes for harsh environment can be used for process-spectroscopy in Near & Mid IR range to monitor reactions in-line in a broad temperature range from -150° to +250°C. They can resist to high pressures up to 200 Bar and used with FTIR or any other IR-spectrometers and spectral sensors in automated process control with process-interfaces.

For more information please visit our “Downloads” section and find relative articles at our “Publications” page.

Specs

Common Parameters of Fiber Optic High Temperature (HT) – ATR-Probes
Total Length 1.5m (opt.: 1m to 5m)*
Shaft Length 300mm (opt.: 300-700mm)*
Shaft Diameter 6.3mm or 12mm
Shaft Material Hastelloy C22
Length of Legs 500mm (opt.: 200mm to 500mm)
Protective Tube Material Liquid Tight SS-Conduit, KOPEX-Tube
Minimal Bending Radius 130mm
Input / Output Connectors Long SMA (opt.: any other type)
Cooling Air Flow Parameters Excess pressure 0.5Bar, Flow 2300l/h
Inner temperature control Inside shaft to control ATR tip temperature
Specification of Fiber Optic High Temperature (HT) – ATR- Probes
Di-ATR Si- ATR ZrO₂- ATR ZnSe-ATR
Probe type
Transmission range 5.2-17μm

600-1900 cm-1

3.2-17μm

600-3100 cm-1

1.1-6.5μm

1550-9000 cm-1

3.2-17μm

600-3100 cm-1

Fiber type PIR-900/1000

Silver Halide

PIR-900/1000

Silver Halide

CIR-500/550

Chalcogenide glass

PIR-900/1000

Silver Halide

Temperature range -150°C / +250°C -150°C / +250°C -150°C / +200°C -150°C / +250°C
Pressure (max) 200 Bar 100 Bar 100 Bar 10 Bar

Downloads

Applications

  • Remote Reaction Monitoring in-line in temperature range -100/+250°C
  • PAT applications in lab, pilot plant or industry with process-interfaces for automated process control
  • Polymerization Process Control
  • In-situ IR-Spectroscopy for PAT in Chemical, Petrochemical, Atomic, Biopharmaceutical & Food Industry

Inquiry