FlexiSpec®

Spectroscopy Fiber Probes & Probe Couplers

FlexiRay®

Fibers | Cables | Bundles | Accessories

FlexiService

Loan & Installation | Measurements Training | Repair | Development
News
Latest News
21 March 2025
Stock Sale: Discounted IR Cables Now Available

We are announcing a stock sale on our high-quality IR fiber cables, now available at discounted prices. Our current offerings include: • Polycrystalline Infrared (PIR) Fiber Cables (3–17 µm)Ideal for applications that require stable infrared transmission over a broad range. • Hollow Glass Waveguide (HGW) Fiber Cables (3–17 µm)Designed for precise light guidance, these cables […]

Read more
11 March 2025
Women in Photonics: Pioneers of Light and Innovation

On International Women’s Day, art photonics GmbH is proud to celebrate the brilliant women driving the photonics industry forward. These accomplished scientists, engineers, and leaders transform light into groundbreaking solutions that advance technology and improve lives. Did you know? At art photonics GmbH, we work alongside visionary women who are making significant contributions to fiber […]

Read more
Latest Events
20 March 2025
Highlights from LASER World of PHOTONICS CHINA 2025

art photonics recently returned from LASER World of PHOTONICS CHINA 2025 in Shanghai. We had the opportunity to engage in meaningful conversations and build new connections around our advanced fiber optics solutions. We appreciate everyone who visited our booth and helped make the event memorable. Looking ahead, we invite you to join us at Laser […]

Read more
12 March 2025
Day 1 at Laser World of Photonics CHINA 2025, Shanghai

We are off to an exciting start in Shanghai at Laser World of Photonics CHINA 2025! Our Sales Director, Haro Fritsche, is on site alongside our fantastic distributor UniqueRay! Today, we are showcasing our innovative system solutions. Visit our booth to explore how our fiber cables and probes span the complete UV-Vis-NIR-MIR range (0.3-16 µm) […]

Read more
Resources
About Our Company
art photonics GmbH, founded in Berlin in September 1998, is one of the worldwide leaders in development and production of specialty fiber products for a broad spectrum from 300 nm to 16 µm. Unique technologies of Polycrystalline Mid InfraRed (PIR-) fibers and Metal coated Silica fibers are used for assembly of various spectroscopy probes for medical diagnostics and industrial process control, in volume production of fiber for medical and industrial lasers, for different fiber bundles, etc. Since January 2024 art photonics GmbH is a member of NYNOMIC GROUP.
Member Of:
UV 200-400 nm
Visible
Near IR 750-2500 nm
Mid IR 2.5 - 18 µm

Fiber Optic ATR-Probes for Harsh Environment

Main features:

  • High throughput in selected parts of Near & Mid InfraRed-spectra
  • ATR-tip shaped for immersion in liquid flow without dead zone
  • Robust for industrial applications in harsh environment up to 250°C
  • Resistant to high pressure
  • Compatible with all spectrometers and automated process-interfaces

Description

Fiber Optic ATR-Probes for harsh environment can be used for process-spectroscopy in Near & Mid IR range to monitor reactions in-line in a broad temperature range from -150° to +250°C. They can resist to high pressures up to 200 Bar and used with FTIR or any other IR-spectrometers and spectral sensors in automated process control with process-interfaces.

For more information please visit our “Downloads” section and find relative articles at our “Publications” page.

Specs

Common Parameters of Fiber Optic High Temperature (HT) – ATR-Probes
Total Length 1.5m (opt.: 1m to 5m)*
Shaft Length 300mm (opt.: 300-700mm)*
Shaft Diameter 6.3mm or 12mm
Shaft Material Hastelloy C22
Length of Legs 500mm (opt.: 200mm to 500mm)
Protective Tube Material Liquid Tight SS-Conduit, KOPEX-Tube
Minimal Bending Radius 130mm
Input / Output Connectors Long SMA (opt.: any other type)
Cooling Air Flow Parameters Excess pressure 0.5Bar, Flow 2300l/h
Inner temperature control Inside shaft to control ATR tip temperature
Specification of Fiber Optic High Temperature (HT) – ATR- Probes
Di-ATR Si- ATR ZrO₂- ATR ZnSe-ATR
Probe type
Transmission range 5.2-17μm

600-1900 cm-1

3.2-17μm

600-3100 cm-1

1.1-6.5μm

1550-9000 cm-1

3.2-17μm

600-3100 cm-1

Fiber type PIR-900/1000

Silver Halide

PIR-900/1000

Silver Halide

CIR-500/550

Chalcogenide glass

PIR-900/1000

Silver Halide

Temperature range -150°C / +250°C -150°C / +250°C -150°C / +200°C -150°C / +250°C
Pressure (max) 200 Bar 100 Bar 100 Bar 10 Bar

Downloads

Applications

  • Remote Reaction Monitoring in-line in temperature range -100/+250°C
  • PAT applications in lab, pilot plant or industry with process-interfaces for automated process control
  • Polymerization Process Control
  • In-situ IR-Spectroscopy for PAT in Chemical, Petrochemical, Atomic, Biopharmaceutical & Food Industry