25 November 2026
NIRaman Combi Probe | Moisture and Polymorphic Form Through One Process Port

Residual moisture and polymorphic form are two critical quality attributes that can change at the same time during API crystallization and drying. Our FlexiSpec® NIRaman Combi Probe measures both in situ through a single process port: a NIR diffuse-reflectance channel for moisture and a 785 nm Raman channel for the solid-state form. Our two-page flyer […]

Read more
5 November 2026
CPACT Webinar Recording | Multimodal Fiber Optic Spectroscopy: Bridging the Gap from Lab to Real-Time Process Control

Our R&D Manager Dr. Alexander Novikov presented the webinar “Multimodal Fiber Optic Spectroscopy: Bridging the Gap from Lab to Real-Time Process Control” on 11 June 2026 as part of the CPACT webinar series. CPACT, the Centre for Process Analytics and Control Technology, is a leading international community focused on Process Analytical Technology (PAT) and advanced […]

Read more
Latest Events
18 November 2026
EAS 2026 Recap | Fiber-Optic ATR: Taking the Mid-IR Fingerprint Region to the Sample

Our CEO, Dr. Stefanie Foerster, represented art photonics at the Eastern Analytical Symposium & Exposition (EAS 2026), held 16–18 November 2026 at the Crowne Plaza Princeton Conference Center in Plainsboro, New Jersey. As announced, she joined our close partner Mustafa Yusuf at the Situs Light booth, #L1. Thank you to everyone who stopped by, from […]

Read more
17 November 2026
Now Open: analytica China 2026 | 16-18 November 2026 | Shanghai New International Expo Centre (SNIEC), China

analytica China 2026 is now open in Shanghai. Until 18 November, you can see art photonics fiber-optic probes in person at Booth # E6.6920, where our distribution partner UniqueRay Technologies Limited (Uray) is presenting our FlexiSpec® probes for inline Process Analytical Technology (PAT) and laboratory spectroscopy. FlexiSpec® probes at the booth The UniqueRay team is […]

Read more
About Our Company
art photonics GmbH, founded in Berlin in September 1998, is one of the worldwide leaders in development and production of specialty fiber products for a broad spectrum from 300 nm to 16 µm. Unique technologies of Polycrystalline Mid InfraRed (PIR-) fibers and Metal coated Silica fibers are used for assembly of various spectroscopy probes for medical diagnostics and industrial process control, in volume production of fiber for medical and industrial lasers, for different fiber bundles, etc. Since January 2024 art photonics GmbH is a member of NYNOMIC GROUP.
Member Of:

NIRaman Combi Probe | Moisture and Polymorphic Form Through One Process Port

Posted on: 
25 November 2026

Residual moisture and polymorphic form are two critical quality attributes that can change at the same time during API crystallization and drying. Our FlexiSpec® NIRaman Combi Probe measures both in situ through a single process port: a NIR diffuse-reflectance channel for moisture and a 785 nm Raman channel for the solid-state form. Our two-page flyer (PDF) summarizes the probe, its applications and its full specifications, together with a statement from Bayer.

Statement from Bayer

Dr. Matthias Balsam, PAT Application Senior Expert at Bayer AG, on the joint work presented at PAT Connect 2026 in Badenweiler:

“In modern pharmaceutical manufacturing, the control of critical quality attributes such as API solid-state form requires robust in-process analytics. As shown at the 2026 TTC PAT-Connect conference, art photonics and Bayer have demonstrated that the combination of Raman and NIR spectroscopy enables simultaneous monitoring of polymorphic form and moisture during key steps such as drying. This integrated PAT approach allows early detection of undesired transformations and supports efficient process development from laboratory to production scale. Innovative solutions – such as combined Raman/NIR probes – are essential to overcome practical implementation challenges and ensure reliable real-time process control.”

— Dr. Matthias Balsam, PAT Application Senior Expert, Bayer AG

Two attributes, two techniques, one port

NIR diffuse reflectance responds strongly to water (the O–H combination band near 1940 nm), so it tracks residual moisture. Raman spectra reflect differences in the crystal lattice, so they distinguish polymorphs. Running both in situ normally takes two probes and two process ports.

The NIRaman Combi Probe places separate NIR and Raman channels in one 19 mm (3/4″) shaft, so both spectra can be acquired synchronously from solids, powders and liquids, without sample preparation. We explain the measurement principle in Dual-Channel Process Monitoring: Combining NIR and Raman Spectroscopy in a Single Probe. For combi probes in a wider PAT context, see the CPACT webinar recording by our R&D Manager Dr. Alexander Novikov.

Applications

  • API crystallization and drying: moisture (NIR) and polymorphic form (Raman) in parallel
  • Real-time reaction monitoring
  • Raw material identification (RMID), see our technical note on RMID with NIR and Raman (PDF)
  • In-process blend potency verification
  • Analytical characterization for the pharmaceutical, food and chemical industries

Specifications

ParameterNIR diffuse-reflectance channelRaman channel
Spectral range1000–2500 nm (other on request)Cut-off 130 cm⁻¹ (other on request)
Laser wavelength–785 nm
Excitation fibersBundle of 19 × NIR400/440, NA 0.22 ± 0.021 × NIR105/125, NA 0.22 ± 0.02
Detection fiber1 × NIR400/440, NA 0.22 ± 0.021 × NIR200/220, NA 0.22 ± 0.02
TerminationsSMA 905FC/PC, SMA 905
ProbeValue
ShaftØ 19 mm (3/4″), 170 mm long
Shaft materialStainless steel 316L, optional Hastelloy C22
WindowSapphire
SealingEpoxy, gold soldering (optional: Kalrez)
Temperature0 to 150 °C
Pressure0 to 10 bar
Stray light< 0.2 %

Flyer and contact

Download the NIRaman Combi Probe flyer (PDF). A pharma-grade configuration is available on request.

Planning Raman/NIR monitoring for crystallization or drying? Send your process conditions (temperature, pressure, medium) and the NIR and Raman spectrometers you use to sales@artphotonics.com.

Related products