FlexiSpec®

Spectroscopy Fiber Probes & Probe Couplers

FlexiRay®

Fibers | Cables | Bundles | Accessories

FlexiService

Loan & Installation | Measurements Training | Repair | Development
News
Latest News
1 December 2024
Happy First Advent from art photonics!

As the first Advent candle burns bright, we reflect on the connection between light and technology. At art photonics, we are committed to advancing remote process control with our fiber probes, which cover a wide spectral range from 200 nm to 18 μm, tailored to meet the needs of modern laboratories and industries. Take a […]

Read more
29 November 2024
2024 BioPhotonics Conference: On-line presentation

We are proud to share the joint presentation by our Senior Advisor & Founder, Viacheslav Artyushenko, and Nazanin M. Shafiee, Director of Strategy and Business Development at Avantes, our valued partner under the Nynomic AG. Their talk at the BioPhotonics Conference, organized by Photonics Media, highlighted cutting-edge advancements in remote spectroscopy for biomedical applications, including: The presentation also emphasized […]

Read more
Latest Events
19 November 2024
Herbstkolloquium Prozessanalytik 2024 | 4–6 December 2024, Merck Darmstadt, Germany

art photonics GmbH is proud to announce its participation in the 19th Herbstkolloquium Prozessanalytik, taking place from December 4–6, 2024, at Merck Darmstadt. We will be showcasing our innovative fiber spectroscopy solutions for in-line process control at Booth №1, including: Additionally, our colleague Andrea Teuber will deliver a presentation, providing insights into the role of […]

Read more
11 November 2024
PIA 2024 | 19-21 November, 2024, Singapore EXPO, Singapore

Join art photonics at PIA 2024 in Singapore! art photonics GmbH, in collaboration with our partner tec5 AG, will be exhibiting at Booth E07 at Process Innovation Asia-Pacific (PIA) 2024. We invite you to visit us to explore our advanced fiber optics technologies for in-line process control. Our Fiber Optic Probes are specifically designed to […]

Read more
Resources
About Our Company
art photonics GmbH, founded in Berlin in September 1998, is one of the worldwide leaders in development and production of specialty fiber products for a broad spectrum from 300 nm to 16 µm. Unique technologies of Polycrystalline Mid InfraRed (PIR-) fibers and Metal coated Silica fibers are used for assembly of various spectroscopy probes for medical diagnostics and industrial process control, in volume production of fiber for medical and industrial lasers, for different fiber bundles, etc. Since January 2024 art photonics GmbH is a member of NYNOMIC GROUP.
Member Of:
UV 200-400 nm
Visible
Near IR 750-2500 nm
Mid IR 2.5 - 18 µm

Fiber Optic ATR Loop Probe

Main features

  • High throughput at Mid InfraRed range
  • On-line absorbance spectroscopy of liquids, pastes & soft solid surfaces
  • Compatible with all FTIR, QCL and IR- Filter spectrometers
  • Cost effective alternative to more expensive ATR-IR-fiber probes
  • Replaceable ATR Loop PIR-Fiber Tips

Description

The ATR-Loop Infrared PIR-fiber probe was the first in FlexiSpec® product line designed for use with FTIR and other Mid IR spectrometers. ATR-Loop PIR-fiber probes are well-suited for remote analysis of composition of liquids, pastes and soft surfaces and do not require sample preparation. The Loop fiber probe is the simplest one in the FlexiSpec® product family to allow for low cost ATR-spectroscopy. Loops with different number of turns (single, double or triple) serve to fit the desired sensitivity.

For a detailed instruction of how to use the Loop Probe, please see:

For more information please visit our “Downloads” section and find relative articles at our “Publications” page.

Specs

Common Parameters of Fiber Optic Multi-Loop Probes FlexiSpec®
Total Length 1m (opt.: PIR up to 5m, CIR up to 10m) *
Shaft Length 120mm *
Shaft Diameter 10,6mm
Shaft Material PEEK
Protective Tube Material PEEK
Input / Output Connectors Long SMA-905 (opt.: any other type)
Detachable PIR fiber Loop Loop; Multi-Loop (Double-, Triple-Loop)
*Customized dimensions are available on request
Specification of Fiber Optic ATR-Loop Probes FlexiSpec®
Probe type Chalcogenide-IR (CIR) Polycrystalline-IR (PIR)
Transmission range 6500 – 1550 cm-1 (1.5-6.0μm) 2500 – 600 cm -1 (4-17μm)
Fiber type Chalcogenide glass (As-S) Silver Halide (AgCl:AgBr)
Temperature range ≤ 90°C ≤ 100°C

Graphs

Downloads

 

Applications

  • Remote evanescent absorption (ATR-) spectroscopy in-citu
  • Multiple ATR-spectroscopy by immersion of fiber loop in liquid
  • In-vivo molecular spectroscopy for medical diagnostics by simple touch of ATR-Loop on skin or tissue

Inquiry

Do you have any questions about this or any other product? Send us an inquiry, and our personnel will answer your question as soon as possible.

linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram
Copy link
Powered by Social Snap