FlexiSpec®

Spectroscopy Fiber Probes & Probe Couplers

FlexiRay®

Fibers | Cables | Bundles | Accessories

FlexiService

Loan & Installation | Measurements Training | Repair | Development
News
Latest News
27 April 2026
Introducing the FlexiSpec Combi Fiber Optic Probes

In the demanding fields of bio-pharma and advanced R&D, real-time data is essential. Traditionally, securing comprehensive analytical data meant physically switching between different spectroscopic setups, such as ATR, NIR, and Raman. This fragmented approach not only slows down critical processes but also introduces a higher risk of sampling errors. Why run three separate analyses when […]

Read more
17 March 2026
Application Note: Identification of Organic and Pharmaceutical Powders

Real-time, in-line powder identification usually means a trade-off between speed and accuracy. We proved it doesn't have to. We recently teamed up with our Nynomic Group partner, m-u-t GmbH, to release a joint Application Note. The goal was simple: build a compact, field-ready NIR setup capable of analyzing complex organics directly in the bulk material, […]

Read more
Latest Events
4 May 2026
EuroPACT 2026 | 4-7 May 2026 | Lyon, France

The 7th European Conference on Process Analytics and Control Technology (EuroPACT 2026) is taking place from May 4th to 7th at the Cité - Centre de Congrès in Lyon, France. art photonics is pleased to announce that our CEO, Dr. Stefanie Foerster, will be attending the event to connect with industry leaders, partners, and innovators […]

Read more
28 April 2026
Day 1 at EPIC AGM 2026 | 28-30 April 2026 | Juan-les-Pins, Nice, France

Bonjour from Juan-les-Pins! Day 1 of the EPIC AGM & Summit 2026 is here, and art photonics GmbH is ready for an incredible event. Our CEO, Dr. Stefanie Foerster, has already engaged in some insightful discussions, kicking things off right alongside Carlos Lee, Director General of EPIC. We extend a warm thank you to the […]

Read more
About Our Company
art photonics GmbH, founded in Berlin in September 1998, is one of the worldwide leaders in development and production of specialty fiber products for a broad spectrum from 300 nm to 16 µm. Unique technologies of Polycrystalline Mid InfraRed (PIR-) fibers and Metal coated Silica fibers are used for assembly of various spectroscopy probes for medical diagnostics and industrial process control, in volume production of fiber for medical and industrial lasers, for different fiber bundles, etc. Since January 2024 art photonics GmbH is a member of NYNOMIC GROUP.
Member Of:
UV 200-400 nm
Visible
Near IR 750-2500 nm
Mid IR 2.5 - 18 µm

Fiber Optic ATR-Probes for Harsh Environment

Main features:

  • High throughput in selected parts of Near & Mid InfraRed-spectra
  • ATR-tip shaped for immersion in liquid flow without dead zone
  • Robust for industrial applications in harsh environment up to 250°C
  • Resistant to high pressure
  • Compatible with all spectrometers and automated process-interfaces
Excel LogoArtphotonics_Sale from stock Probes March 2026

Description

Fiber Optic ATR-Probes for harsh environment can be used for process-spectroscopy in Near & Mid IR range to monitor reactions in-line in a broad temperature range from -150° to +250°C. They can resist to high pressures up to 200 Bar and used with FTIR or any other IR-spectrometers and spectral sensors in automated process control with process-interfaces.

You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.

More Information

For more information please visit our “Downloads” section and find relative articles at our “Publications” page.

Specs

Common Parameters of Fiber Optic High Temperature (HT) – ATR-Probes
Total Length 1.5m (opt.: 1m to 5m)*
Shaft Length 300mm (opt.: 300-700mm)*
Shaft Diameter 6.3mm or 12mm
Shaft Material Hastelloy C22
Length of Legs 500mm (opt.: 200mm to 500mm)
Protective Tube Material Liquid Tight SS-Conduit, KOPEX-Tube
Minimal Bending Radius 130mm
Input / Output Connectors Long SMA (opt.: any other type)
Cooling Air Flow Parameters Excess pressure 0.5Bar, Flow 2300l/h
Inner temperature control Inside shaft to control ATR tip temperature
Specification of Fiber Optic High Temperature (HT) – ATR- Probes
Di-ATR Si- ATR ZrO₂- ATR ZnSe-ATR
Probe type
Transmission range 5.2-17μm

600-1900 cm-1

3.2-17μm

600-3100 cm-1

1.1-6.5μm

1550-9000 cm-1

3.2-17μm

600-3100 cm-1

Fiber type PIR-900/1000

Silver Halide

PIR-900/1000

Silver Halide

CIR-500/550

Chalcogenide glass

PIR-900/1000

Silver Halide

Temperature range -150°C / +250°C -150°C / +250°C -150°C / +200°C -150°C / +250°C
Pressure (max) 200 Bar 100 Bar 100 Bar 10 Bar

Downloads

Applications

  • Remote Reaction Monitoring in-line in temperature range -100/+250°C
  • PAT applications in lab, pilot plant or industry with process-interfaces for automated process control
  • Polymerization Process Control
  • In-situ IR-Spectroscopy for PAT in Chemical, Petrochemical, Atomic, Biopharmaceutical & Food Industry

Inquiry

Do you have any questions about this or any other product? Send us an inquiry, and our personnel will answer your question as soon as possible.

We use the Mailchimp service (Intuit Inc., USA) to distribute our newsletter. Your data is used exclusively for the purpose of sending the newsletter and will be processed based on your consent (Art. 6 para. 1 lit. a GDPR). Mailchimp may also process data in the United States. Please note that the USA is considered a third country without an adequate level of data protection. For more information, please refer to Mailchimp’s Privacy Policy: https://mailchimp.com/legal/privacy/ .
crossarrow-right
linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram
Copy link
Powered by Social Snap